ONYX provides maintenance services and develops an annual maintenance plan, including equipment inspection, cleaning, and performance testing, to ensure long-term stable operation.
2025-07-28
When a device malfunctions, first refer to the "Common Troubleshooting" section in the "Operation and Maintenance Manual" and attempt to resolve the issue yourself. If you are unable to resolve the issue, contact after-sales service for technical support through the product manual or the headquarters and factory 400 phone numbers provided on the official website. It's recommended that you keep a record of the malfunction to facilitate efficient communication.
2025-07-28
Common parts are delivered nationwide within 48 hours, and specialized parts are stocked in advance to minimize downtime.
2025-07-28
Professional Team: Equipped with a highly qualified technical team, we provide rapid response and remote/on-site support.
Regular Maintenance: We develop preventive maintenance plans and regularly check equipment status.
Spare Parts Supply: We maintain a stock of genuine spare parts to shorten repair cycles.
Training: We provide operation and maintenance training to enhance our customers' operational capabilities.
Warranty Commitment: We strictly honor warranty terms and offer free repair or replacement for non-intentional damage.
2025-07-28
1. Power trip/indicator light off: Check the wiring and replace the leakage circuit breaker/power switch/fuse.
2. UV lamp off/alarm light abnormal: Replace or repair the ballast/lamp, and replace the LED.
3. UV-254 monitor malfunction: Check the wiring/replace the transformer, and clean the quartz sleeve.
4. Excessive condensate discharge: Drain the condensate from the gas storage tank and filter.
5. H2O2 tank overflow: Stop the dosing pump and wait for the overflow to complete.
2025-07-28
Check the seals of the housing and hood for leaks, mark the leaks, and seal them with glue. Check the air pipes for signs of aging and leaks, and replace them promptly. Repair or replace damaged seals and connectors.
2025-07-28
First, disconnect the power supply and check for loose connections. Replace damaged fuses, power switches, and other components. If the PLC or human-machine interface is faulty, consult a qualified technician and replace the component if necessary.
2025-07-28
Possible causes include a malfunction in the pneumatic drive system, an air compressor failure, impact from cylinder movement, or a guide rod fault. Other possible causes include air leakage from pneumatic components, excessive cylinder speed, and guide sleeve wear.
2025-07-28
Check the water quality. If low UV transmittance, high iron content, or high levels of suspended solids are detected, pretreatment is necessary. Clean the quartz sleeve. Check the lamp for damage and replace it promptly. Adjust the cleaning cycle. Ensure the equipment is operating at the specified temperature and flow rate.
2025-07-28
Check the power supply: Confirm that the main power and control power are connected and there are no tripped or damaged fuses.
Check the lamp connection: Ensure that the lamp plug is fully inserted into the ballast socket and is not loose or in poor contact.
Replace the lamp: If the lamp is damaged (such as a broken or cracked filament), replace it with a new one.
Check the ballast: If the ballast is faulty, replace it and retest.
Check the alarm message: Use the human-machine interface to identify the specific cause of the fault.
Note: Always disconnect the power cord and wear protective equipment during operation.